Environment Monitoring System AC & DC Power Monitors
Power Relays & Sensors compatible with ENVIROMUX-2D, ENVIROMUX-5D and ENVIROMUX-16D
AC & DC Monitors
AC & DC Voltage & Current Monitor
The AC & DC Voltage & Current Monitor measures and reports AC and DC voltage, and reports AC and DC current measured with attached Hall-Effect transducers (sold separately) to the ENVIROMUX-2D/5D/16D unit.
- Reports AC voltage, AC current, DC voltage and DC current.
- Current measurements require Hall-Effect transducers (sold separately).
- Polling rate: 1Sa/s.
- Common applications include: electrical systems, power equipment, battery monitoring, generators, remote sites, controlled environment vaults (CEVs), building automation, data center, cabinets, telecom, substations, storage power supplies, communication huts, indoor/outdoor lighting, power distribution, and medical and test equipment.
- AC voltage 2-pin terminal block
- 0 to 240VAC 600V isolated
- 0.25VAC resolution
- Accuracy
- 0 to 220VAC: 2.5VAC accuracy
- 220 to 240VAC: 5.0VAC accuracy
- DC voltage 2-pin terminal block
- -60 to +60V DC non-isolated
- 0.12VDC resolution
- 1.2VDC accuracy
- One rectifying Hall Effect 4-pin transducer interface for measuring AC current
- 0.2% resolution
- Accuracy and range are transducer-dependent (sold separately).
- One non-rectifying Hall Effect 4-pin transducer interface for measuring DC current
- 0.2% resolution
- Accuracy and range are transducer-dependent (sold separately).
- Supports CAT5/5e/6 cable up to 1,000 ft (305 m).
- Dimensions WxDxH (in): 6.2x2.3x1.6 (158x58x41 mm).
- Current consumption: 8mA @ 5VDC, 66mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS.
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend the monitor up to 1.2 miles (2km) from the ENVIROMUX unit.
DC Line Monitor
The DC Line Monitor measures DC voltage and reports DC current measured with attached Hall-Effect transducers (sold separately) to the ENVIROMUX-2D/5D/16D unit.
- Reports DC voltage and DC current.
- Current measurements require Hall-Effect transducers (sold separately).
- Polling rate: 1Sa/s.
- Six 2-pin terminal blocks for measuring DC voltage
- Non-isolated -60 to +60V DC
- 0.12VDC resolution
- 1.2VDC accuracy
- Six non-rectifying Hall Effect 4-pin transducer interfaces for measuring DC current
- 0.2% resolution
- Accuracy and range are transducer-dependent (sold separately).
- Supports CAT5/5e/6 cable up to 1,000 ft (305 m) (18-24 AWG).
- Current consumption: 190mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- The ENVIROMUX-DCLM-6 may require more power than the RJ45 sensor ports can supply on the ENVIROMUX-2D/15D/16D.
- Refer to page 2 of the manual to determine if the optional PWR-SPLY-12V1A power supply is necessary for your configuration.
- The ENVIROMUX-DCLM-6 may require more power than the RJ45 sensor ports can supply on the ENVIROMUX-2D/15D/16D.
- Dimensions WxDxH (in): 6.82x3x1.71" (173x76x43 mm).
- Regulatory approvals: CE, RoHS.
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2km) from the ENVIROMUX unit.
AC Power Monitor with Relay
- Reports AC Voltage, Frequency, Power, and Current.
- Monitors Power from one AC inlet to one AC outlet, between 50~250VAC and 47~63Hz.
- Monitors the number of swells, sags, and spikes.
- Monitors swell and sag duration of 0.1 second to 1 minute.
- Includes Relay with configurable disconnect settings: threshold reboot, or manual reboot.
- Accuracy
- Voltage accuracy: ± 1%
- Frequency accuracy: ± 1%
- Current accuracy: ± 1%
- Outlet Max load rating (continuous):
- ENVIROMUX-ACLM-P18 (US/Canada): 18A rated load, 20A maximum.
- ENVIROMUX-ACLM-P12 (US/Canada): 12A rated load, 15A maximum.
- ENVIROMUX-ACLM-P8 (Euro/UK): 8A rated load, 10A maximum.
- Capable of measuring current surges from 300 mA to 20A.
- User defined minimum and maximum voltage and power thresholds.
- Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
- Cables included:
- ENVIROMUX-ACLM-P12/8: one country-specific IEC 320 C13 line cord, and one IEC 320 C14 to IEC 320 C13 cord set for connection to AC load.
- ENVIROMUX-ACLM-P18: one L6-20r to IEC 320 C20, and one L6-20p to IEC 320 C19.
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m).
- ENVIROMUX-2D/5D: supports CAT5/5e/6 cable up to 750 ft (229 m).
- Dimensions (WxDxH) in:
- ENVIROMUX-ACLM-P12/8: 7.0x5.5x1.65 (178x140x42 mm).
- ENVIROMUX-ACLM-P18: 7.0x6.5x1.65 (178x165x42 mm).
- Weight: 1.6 lbs (726 g).
- Current consumption: 13mA @ 5VDC, 125mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
AC Dual Voltage Monitor
- Reports AC Voltage and Frequency.
- Monitors AC voltage and frequency on two AC inlets between 50~250VAC and 47~63Hz.
- Monitors the number of swells, sags, and spikes.
- Voltage accuracy: ± 1%
- Frequency accuracy: ± 1%
- User defined minimum and maximum voltage thresholds.
- Capable of detecting user selected spike events with a peak greater than 50V, 250V, 500V, or 1KV.
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m).
- Current consumption: 70mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
DC Voltage Monitor
- Monitors up to two DC voltages: -60VDC ~ 0VDC or 0VDC ~ 60VDC
- Accuracy: ± 100mV ± 1% reading
- Connector: Screw Terminal, 5-position
- Supports CAT5/5e/6 cable up to 1,000 ft. (305 m)
- Includes Mounting Hardware
- Operating temperature: 32 to 158°F (0 to 70°C).
- Current consumption: 30mA @ 12VDC.
- Powered by ENVIROMUX-2D/5D/16D.
- Regulatory approvals: CE, RoHS
- Compatible with ENVIROMUX-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.