1-Outlet Remote Power Reboot Switch control power on off reboot IP CAT5 Web
PWR-RMT-RBT-LC (Front & Back)
PWR-RMT-RBT-LC (Front & Back)

Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet

NTI Part #: PWR-RMT-RBT-LC-Group
The Remote Power Reboot Switch allows you to remotely reboot and control power (on/off) to a server or other powered device over IP. Control via web interface, AutoPing, Telnet, or DxP (Dataprobe Exchange Protocol). Regulatory approvals: CE, UL, cUL, FCC, RoHS.
Also known as: remote reboot CAT5, Web remote power, remote power switch, remote reboot over ip, control power on off
Product Highlight
  • Remotely control power on/off/reboot to any remote device over IP
  • Control via web interface, AutoPing, Telnet, or DxP
  • Regulatory approvals: CE, UL, cUL, FCC, RoHS

Talk to a live agent

  • ROHS Compliant Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet
  • CE Compliant Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet
  • FCC Compliant Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet
Scroll Down to Get Quote

Overview

The ENVIROMUX® Remote Power Reboot Switch allows you to remotely reboot and control power (on/off) to a server or other powered device over IP.

  • Regulatory approvals: CE, UL, cUL, FCC, RoHS.
  • Auto-scheduler allows for scheduling power on/off/reboot events.
  • Easy-to-use web interface makes it easy to control power from anywhere in the world.
  • Access an unlimited number of Remote Power Reboot Switches from one software application.
    • The Device Management Utility detects and displays all PWR-RMT-RBT-LC on a network and enables individual assignment of IP addresses, upgrading of firmware, and loads the web browser of any selected unit.
  • Multiple control options: Web interface, AutoPing, Telnet, DxP (Dataprobe Exchange Protocol)
    • The DxP protocol allows developers to design and integrate the PWR-RMT-RBT-LC into custom applications
  • Auto-ping up to 2 IP addresses:
    • Local ping: automatically reboots device if there is no response.
    • Remote ping: pings a remote host and powers up alarm or connected device when there is no response.
  • Dual password protection with separate user and administrator passwords.
  • A Windows batch file can be used to automatically power on/off/reboot the device
  • Optional wall mount and DIN mount kit available.
  • The Remote Reboot Switch is the ideal solution for many applications, such as:
    • Remote reboot of any device, router, server, kiosk, etc. The device need not be network attached.
    • Secure sensitive devices by keeping them powered off when not in use. This prevents hackers from detecting them at all times.
    • Power down equipment when not needed for power savings and to save on wear and tear.
    • Power up alert devices like sirens, lamps, and messages, or environmental system like heaters, coolers, pumps, etc.

Specifications

Power
  • 105-240 VAC auto ranging.
  • Power switching: up to 12 Amps at 105-125 VAC, 10 Amps at 210-240 VAC.
  • Input connector: one IEC 320 C13 plug
  • Output connector: one IEC 320 C14 receptacle
  • Includes line cord and extension cord
    • PWR-RMT-RBT-LC includes a 12A US line cord.
    • PWR-RMT-RBT-LC10A includes a 10A country-specific line cord.
Network Interface
  • One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
  • Autosensing uplink/downlink
  • 6 ft (2 m) CAT5 cable included
Protocols
  • HTTP, TCP/IP, DHCP
  • Built-in Telnet server
  • DxP Messaging Protocol
  • Auto-ping TCP Protocol
MTBF
  • 360,000 hrs
Environmental
  • Operating temperature: 32 to 122°F (0 to 50°C)
Dimensions
  • WxDxH: 2.0x3.2x4.2 in (60x82x107 mm)
  • Weight: 0.54 lbs (244 g)
  • Optional wall mount and DIN mount kit available (MK-PWRRMTRBTLC).
Regulatory Approvals
  • CE, UL, cUL, FCC, RoHS
  • EN51055, EN50121-3-2
Warranty
  • Two years

Control Methods

Web Interface
  • Configuration can be done over the Internet/LAN via Web page.
  • View/edit device and AutoPing settings.
    • Ping up to two IP addresses.
  • View/edit event schedules and manually control the connected device.
    • Up to eight individual schedules events can be programmed.
    • Events are configured with date, time, repeat, and action functions.
  • Configure IP information (address, subnet mask, default gateway, etc.) and user administrative settings.
Command Line Interface (CLI)
  • Remote administration and control of the unit using Telnet protocol.
    • Requires a Telnet client program.
  • View/edit device and AutoPing settings.
    • Ping up to two IP addresses.
  • View/edit event schedules and manually control the connected device.
    • Up to eight individual schedules events can be programmed.
    • Events are configured with date, time, repeat, and action functions.
  • Configure IP information (address, subnet mask, default gateway, etc.) and user administrative settings.
Windows Batch Script
  • Use a Windows batch file to automatically power
    on/off/reboot the connected device.
    • E.g. a status monitor program can be used to detect faults and then trigger a reboot when preset parameters are not met.
  • Below are two files for running the demo script to integrate the Windows batch file with the PWR-RMT-RBT-LC.
  • Commands can be added or modified in the script depending on the requirement.
    • A list of available commands is in the manual.
  • To execute the demo, enter the following into the Windows command prompt: dir>trigger.bat

Application Drawings

  • How to remotely control power on/off/reboot to a server, router, web cam, firewall or other remote device over IP.
    How to remotely control power on/off/reboot to a server, router, web cam, firewall or other remote device over IP.
  • Remote Power Reboot Screen Shots
    Loading image...

(0)Low-Cost Remote Power Reboot Switch

NTI Part # Description Location Qty
PWR-RMT-RBT-LC Low-Cost Remote Power Reboot Switch with 12A US Line Cord US/Canada
PWR-RMT-RBT-LC10A Low-Cost Remote Power Reboot Switch with 10A Country-Specific Line Cord Euro/UK
MK-PWRRMTRBTLC Wall Mount and DIN Mount Kit N/A
Top Please enter a quantity of at least one product